2 Hr Rated Roof Assembly

1 Hour Assembly Illustration Roof Covering Roof Construction

1 Hour Assembly Illustration Roof Covering Roof Construction

Image Result For 2 Hour Fire Rated Floor Ceiling Assembly Stud Walls Wood Studs Floor Ceiling

Image Result For 2 Hour Fire Rated Floor Ceiling Assembly Stud Walls Wood Studs Floor Ceiling

Pin By Rion Philbin On Bs Exterior Wall Cladding Wall Cladding Floor Ceiling

Pin By Rion Philbin On Bs Exterior Wall Cladding Wall Cladding Floor Ceiling

09 21 16 435 Gypsum Board Assembly Wall Floor Intersection Non Rated Ceiling Partition Dynamic Ceiling Detail Roof S Duct Work

09 21 16 435 Gypsum Board Assembly Wall Floor Intersection Non Rated Ceiling Partition Dynamic Ceiling Detail Roof S Duct Work

09 21 16 434 Gypsum Board Assembly Wall Floor Intersection Non Rated Partition At Rated Duct Work Ceiling Detail Grid Panel

09 21 16 434 Gypsum Board Assembly Wall Floor Intersection Non Rated Partition At Rated Duct Work Ceiling Detail Grid Panel

This Classic Example Of A Two Hour Fire Rated Assembly Has Two Independent Stud Walls Each With Fiberglass In The Stu Design Build Firm Building Design Design

This Classic Example Of A Two Hour Fire Rated Assembly Has Two Independent Stud Walls Each With Fiberglass In The Stu Design Build Firm Building Design Design

This Classic Example Of A Two Hour Fire Rated Assembly Has Two Independent Stud Walls Each With Fiberglass In The Stu Design Build Firm Building Design Design

Concrete with cellular steel 3 hr.

2 hr rated roof assembly.

Stc description system rating test no. Ul p533 roof ceiling one layer 5 8 15 9 mm fire shield c ga rc 2603 wallboard attached to 1 2 12 7 mm resilient furring channel spaced 12 o c. These assemblies need to meet fire and smoke safety and environmental sustainability requirements. These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.

Our cad and revit library of design drawings of wall intersections joints and other construction details. These listings are short summaries to serve as a. Fire rated wall floor and ceiling assemblies provide the necessary fire and smoke barriers to create compartmentalization during a fire safeguarding against the spread of fire and smoke within a building or to and from a building. 1 2 12 7 mm toughrock fireguard c or 1 2 12 7 mm densarmor plus fireguard c gypsum panel applied perpendicular to resilient channels 24 610 mm o c.

Gypsum wallboard roof ceilings wood framing pitched roof truss 11 1 hr. Ibc table 721 3 item 21 1 1 describes a single prescriptive 1 hour rated floor or roof assembly that includes wood trusses. 276 fire rated ceiling assemblies suspension ceiling designs floor ceiling designs a003 3 hr. All new fire rated roof ceiling assembly files.

With 1 2 wood structural panels with. Screw fastened perpendicular to lower chord of wood trusses of 2 x 4 38 mm x 89 mm. 3 4 fr 83 12 x 12 z runners fluorescent type none 2 1 2 concrete. With 1 25 mm type s drywall screws 12 305 mm o c.

Shaft wall limiting heights spans. Wood joists wood i joists floor trusses and flat or pitched roof trusses spaced a maximum 24 o c. V337 2 hour interior wall assembly ul design no. Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.

2 hour exterior wall assembly ul design no. 12 x 24 2 x 4 8 w10 x 25 beam floor units and beam support 3 hr. Find usg product specific cad and revit files. 6 usg fire resistant assemblies test certiļ¬cation test conditions and fire and sound tested assemblies listed in this selector are based on characteristics properties and performance certificationof materials and systems obtained under controlled test conditions as set forth in the appropriate astm standard in effect at the time of test.

Lp flameblock fire rated osb sheathing is a component of the following code compliant fire rated assemblies. Wd stud 2 layers 5 8 sheetrock brand gypsum n a j panels firecode core outside both sides 5 8 sheetrock brand gypsum panels firecode core inside both sides 2 rows 2 x 4 24 o c base layer.

Pin On Construction

Pin On Construction

Exterior Wall Assembly In Specification Exterior Insulation Cavity Insulation Metal Siding

Exterior Wall Assembly In Specification Exterior Insulation Cavity Insulation Metal Siding

Roof Access Hatch Thermally Broken Roof Access Door Roof Access Hatch Roof Hatch Roof

Roof Access Hatch Thermally Broken Roof Access Door Roof Access Hatch Roof Hatch Roof

Pin By Grzegorz Salapa On Techniczne Wood Truss Plates On Wall Wall Board

Pin By Grzegorz Salapa On Techniczne Wood Truss Plates On Wall Wall Board

Source : pinterest.com